Flow Through Helical Coil Apparatus
The Helical coils are used for heating or cooling in process tanks. When a fluid flows through a curved tube, centrifugal force acting upon the various elements of fluid moving with different velocities causes secondary circulation. Secondary flow results in higher heat transfer characteristics. Further, secondary flow stabilizes the laminar flow leading to a higher critical Reynolds number for transition from laminar to turbulent flow.
Technical Specification :-
• Helical Coil : Material Stainless Steel Dia – 12"
• No. of Turns : 14
• Coil Tube Dia : OD 21mm, ID 16mm (Approx.)
• Sump Tank : Material Stainless Steel, Capacity 50 Ltrs.
• Water Circulation : FHP Pump, Crompton/Sharp make.
• Pressure Drop Measurement : By Manometer
• Flow measurement : Rotameter.
• Piping : GI and PVC
• Control panel comprising of : Standard make On-off switch, Mains Indicator etc.