Fluidized Bed Heat Transfer Unit
The set up consists of a glass column partially filled with sand. A heater in the form of cylinder is placed in the bed to heat the sand. Blower Air supply is feed at the bottom of the column. Flow rate of air is measured using orificemeter and manometer. The heater input can be controlled by the Digital Temperature Controller. Temperature sensors are provided to measure the temperature of air inlet and air outlet.
| Column |
Material Borosilicate Glass
|
| Heater |
Made of Nichrome Wire
|
| Air Flow Measurement |
By Orificemeter & manometer
|
| Control panel comprising of Digital Temp Controller |
PID Controller,0 to 199.9 deg C
|
| Digital Temp Indicator |
0 to 199.9 deg C,with multi channel switch
|
| Temperature sensors |
RTD PT-100 type-3Nos.
|
| Electricity Supply |
1 Phase,220 V AC,50 Hz,5-15 Amp.
|